Registers and the check-in tablet work through the store server PC at your front desk. When one cannot reach it, the cause is almost always that PC, the shop network, or the security certificate the device must trust.
Symptoms
- A cloud with a cross in the register's top bar, and the message Your data will sync when you're reconnected.
- The POS does not open in the register's browser, or the browser warns that the connection is not private.
- A password prompt answers The store server cannot be reached, so the password cannot be checked.
- The register opens on the Activation Code screen, or says Failed to authenticate. Please activate your device again.
- The check-in tablet cannot check customers in.
Likely causes
- The store server PC is off, asleep or signed out
- Registers need that PC on, awake and signed in to Windows, with EraPOS running. Closing the EraPOS window is fine; signing out of Windows or shutting the PC down is not.
- A different network
- The device is on another network, such as guest Wi-Fi, or the shop network is down. The store server only accepts devices on its own shop network.
- The certificate is not trusted
- Each register must trust the store server's own security certificate, which the connection kit installs. Without it, the browser refuses the connection.
- The address changed or the certificate expired
- The connection kit opens a fixed address, and the store server lets registers in only on the network address it was set up with. A new router or network can change that address. The certificate itself lasts two years.
- The register needs activating again
- On a store connected to EraPOS Control, a register that cannot confirm its activation asks for its code again.
Fix
- Check the store server PC
Make sure it is on, awake and signed in, and that the POS works in the EraPOS window there. If EraPOS is not running, start it with EraPOS.exe.
- Check the network
Put the device on the same shop network as the store server PC. If no register can connect, look at the store server PC and the router; if only one cannot, look at that device.
- Reconnect with the connection kit
On a Windows register, run Connect from the connection kit again: it checks the certificate, trusts it for that Windows user and opens the POS at the right address. On a tablet, trust the store server's certificate in the tablet's settings and open the same address. Never continue past a certificate warning.
- Activate if asked
Type the register's Activation Code and choose ACTIVATE. If you do not have the code, EraPOS support can give it to you.
- Let it catch up
When the cloud disappears, a spinning circle shows while the register sends what it saved. Do not clear the register's browser data before it finishes.
Result
The register shows the Service Board without the cloud, and changes made on any register appear on the others by themselves.
Still stuck?
Note
A changed address, an expired certificate or a firewall change is fixed on the store server PC and needs an updated connection kit. Open a support request and tell us which devices cannot connect and what they show. Meanwhile, registers keep selling from their own copy: see Working offline.